TenderMemo
EN PL

Poland / Public procurement

Military tenders with no bids

Edition

Warehouse workers preparing parcels at Sharpe Army Depot in 1987
Archive photo · U.S. National Archives · 1987 · Public domain
108 Source links

Executive summary

New results since the last successful report from 01.11.2026, 18:28:11 Europe/Warsaw. Publication checks 31.10–02.11 cover at least 48 hours of overlap; earlier dossiers are not repeated.

Procurement status reflects the date of this edition. Current terms are available from the contracting authority.

Daily update · physical deliveries only · 02.11.2026

New results since the last successful report from 01.11.2026, 18:28:11 Europe/Warsaw. Publication checks 31.10–02.11 cover at least 48 hours of overlap; earlier dossiers are not repeated.

5 new contract award notices · 41 new lots without bids · 3 procedures covered by today's delta
2 procedures appearing in the report for the first time; 39 new lots in known 31 WOG 59/ZP/26
1 active formal reissue · 1 URGENT
Net values of the relevant 41 lots not disclosed — total cannot be determined.

No amounts were attributed from contracts awarded in other lots or historical values to reissues. Missing value does not mean 0 PLN. All new results were published 02.11.2026.

Three opportunities to prepare for

  • 10 WSK 115/2026 — REISSUED / URGENT: entire five-item order for renal replacement therapy fluids, deadline 04.11, 08:00. An authorised pharmaceutical partner, full compliance and a functioning platform are required.
  • 31 WOG, task 50: two hardware pulse oximeter simulators; an actual Polish channel and OEM were found. Before bidding, confirm the full configuration, including accessories and the auxiliary licence.
  • 31 WOG, task 61: two 3 l transport warmers; an actual Polish product channel and foreign OEM exist. The historical call is closed — prepare for a possible new notice; this is not a bid now.

REISSUED / URGENT — entire 10 WSK 115/2026

Deadline: 04.11.2026, 08:00 Europe/Warsaw (CET). The previous 03.11 is outdated: the change of 26.10 moved the deadline. The old 69/2026, task 1 / LOT-0001 → entire current 115/2026. The bid must cover all five items.

The formal succession is confirmed by the procurement specifications, which describe the previous division into three tasks and the absence of bids for this assortment. Comparison of both price schedules confirmed the same five items, packaging, quantities and connectors, with the subsequent potassium change noted below.

ItemPhysical productPackagingBase: op.Option: op.
1Two-compartment hemofiltration solution 4,75 + 0,25 l; ready-to-use 5 l. After the change, K0/K2/K4.2 × 5 l10050
2CRRT dialysate without phosphate, K2/K4.2 × 5 l75003750
3CRRT dialysate with phosphate, K2/K4.2 × 5 l31001550
4Sodium citrate 4%, medicinal product.8 × 1500 ml800400
5CaCl₂ dihydrate, 100 mmol/l, 300 mOsm/l, pH 5–7, medicinal product.8 × 1500 ml240120

Confirmed: compatibility with Fresenius Multifiltrate CICA M201271 and PRO M205001; SecuNect, or, if unavailable, SafeLock with at least 1 adapter per 24 dialysate bags. Clarification 26.10 allowed K0/K2/K4 in item 1 instead of the discontinued K3, with the other parameters unchanged. The old price schedule must not be read without this clarification.

Requirements of the current call: bid and documents in Polish, qualified electronic signature, e-ProPublico account; price 100%. Bid form and price schedule, ESPD, sanctions, representation, product data sheets, declarations of authorisation and compatibility. Upon request, including GIF licence hurtowni/składu, Criminal Record Certificate, US/ZUS and register. No bid bond or performance security; no separate threshold obrotu/referencji in the condition reviewed. Legal authorisation for medicinal products to be marketed in Poland and the relevant medical device documents are required.

Performance and risks: 36 months, option of up to 50% of the quantity i/lub for up to 12 months within the contract limit; guaranteed minimum 60% of the base value. Delivery within 2 business days to the pharmacy, level −1, Powstańców Warszawy 5, Bydgoszcz, with transport and unloading at the contractor's expense. Shelf life ≥12 months; shorter only with prior consent. Payment in 60 days. Delay penalty 1% of the value of the undelivered partii/dzień, penalty cap 20% of the contract; additional damages may be claimed. Stock availability and full compliance of a specific SKU set have not been confirmed.

Significant technical gap: the official documents page and files work; the exact bid submission page e-ProPublico returned HTTP 503 in ordinary public checks. Bid submission functionality unconfirmed. We do not present a non-functioning address as a verified link. No account was registered and no login was attempted.

What to do now — practical recommendation

  1. Download the complete set of documents from page 73909, the deadline change and clarification 26.10; restore working access to the relevant bid submission page e-ProPublico before deciding whether to bid.
  2. Secure a commitment from a GIF-authorised partner for all five items, bazy/opcji, connectors and adapters, shelf life, and deliveries within 2 business days.
  3. Match specific Polish SKUs and data sheets, authorisations, compliance and compatibility. For item 1, take the permitted K0/K2/K4. into account
  4. Price the full basket including VAT, transport, 60-day financing, minimum receipt of 60% and penalties; prepare the ESPD, sanctions and representation documents.
  5. Only after confirming the platform, authorisations and compliance of every item, sign using a qualified electronic signature and submit before 04.11 at 08:00, retaining the EPO. Otherwise NO-BID.

Assessment: PARTNER REQUIRED / URGENT. Authorised Polish pharmaceutical channel + actual OEM. OEM reseller authorisation is not a confirmed additional tender requirement here; written delivery support is a commercial recommendation. Contact: Barbara Baranowska, orders, , +48 261 417 364.

Official documents page · Current procurement specifications · Price schedule · Deadline change · Clarification K0/K2/K4 · Draft contract

Main table — new lots without bids only

Each listed lot has an exact official reason: “No tenders, requests to participate or designs were received” and the status “No winner was selected and the competitive procedure was closed.” This is not merely a statistical zero in the bids category.

Publication / resultContracting authority / locationSubject / lots / categoryNetOriginal deadlineReason / reissueContact / sourcesAssessment / structure
02.11.2026
759231: lots 21,27,29,35,37,38
756443: 43,44,47–51,53,55–57,60
758314: 61–63,65,69,71,72,74,77–80,83–85,87–92
31 Military Economic Unit
Zgierz, Konstantynowska 85
59/ZP/26 — procedure already known; today, 39 other lots.
Medical equipment, accessories, physical simulators and equipment.
39 lots / 126 product lines — exact map below. Auxiliary software embedded in devices, not a standalone service.
Not disclosed for any of the 39 lots.14.07.2026, 10:10 Europe/Warsaw; historical call closed.Exact reason above for each specified lot.
No active formal reissue of these 39 lots was identified within the scope checked.
Margareta Morawska-Raczyńska

+48 261 442 185 (procurement specifications)
Procurement specifications and original annexes
Original notice
WORTH PREPARING FOR / PARTNER REQUIRED; gaps in NO-BID.
Specialist medyczny/symulacyjny or multi-OEM integrator; no requirement for one manufacturer for the entire task.
02.11.2026
757617-2026
10 Military Clinical Hospital with Polyclinic, Independent Public Healthcare Institution
Bydgoszcz
69/2026
LOT-0001 / task 1 — hemofiltration fluids for use with Multifiltrate CICA and PRO.
Medicines and fluids for renal replacement therapy.
Not disclosed. Amounts from winning lots 2/3 were not carried over.07.08.2026, 08:00 Europe/Warsaw — historical.Exact reason above.
REISSUED / URGENT: old task 1 → entire 115/2026; deadline 04.11.2026, 08:00.

+48 261 417 364
Current 115/2026
Original 69/2026
PARTNER REQUIRED
Authorised Polish pharmaceutical channel + OEM; complete five-line basket, no partial bid.
02.11.2026
758873-2026
WIM-PIB — military representative for the joint purchase
Co-purchasers: USK Białystok, UCK Gdańsk, USK4 Lublin.
74/ZP/26 / P/307/2026/SZ/WIM/MZ
LOT-0017 = lot 16 — Chair, standard training chair with writing tablet, 36 units
18 Białystok + 18 Lublin, not delivery to Szaserów in Warsaw.
Equipment for tactical medicine training rooms.
Not disclosed for lot 16.28.07.2026, 10:00 Europe/Warsaw — historical.Exact reason above.
Historical formal reissue 110/ZP/26: deadline 12.10, 10:00 has already passed. Not counted as aktywne/PILNE.

+48 261 816 051
Correct record 74/ZP/26
Historical 110/ZP/26
WORTH PREPARING / MONITORING; NO-BID without a full match.
Furniture OEM or appropriate supplier; civilian recipients explicitly participate in the military lead purchaser’s joint procurement.

31 WOG — exact map of 39 new lots

All items below are physical supplies. Net value of each lot not disclosed. The option for up to 100% of the base scope applies in today’s delta only to task 69; the remaining 38 new lots have no option according to the procurement specifications reviewed. The models listed are candidates for confirmation, not accepted equivalents.

Lot / categoryConfirmed basket / quantitiesSources of supplyGap / decision
21. Other – E
Medical supplies
25 containers 1 l; 20 adult cricothyrotomy kits; 700 NPA 6,5 and 100 NPA 7,0 with lubricant; 100 X-ray drapes 45×45; 10 Cystofix; 20 Quicktrach 4,0; 30 gels 11 mlA06, A07, A14, A15, A18, A22REQUIRES PARTNER / NO-BID to complete the full basket
Multi-product basket is incomplete. Quicktrach with cuff requires version II, not automatically I. The Cystofix specification includes ' needle length 120m' – clarify the unit; do not amend it without authorisation.
27. Adapters
Oxygen and capnography accessories
2 Pin/Index Connector Oxygen Stem; 2 EMMA Airway AdapterA11NO-BID required to identify both adapters
EMMA population and interfejsu/urządzenia for Pin Index not specified. EMMA adult/pediatric and infant are different products. Pin Index – no exact SKU identified.
29. Catheters, connectors, gels, kits
Medical supplies
18 lines: suction catheters CH14/18 at 100 each; silicone Foley CH14/16/18 at 100 each; connectors 50; connectorsO2 30; nasal cannulasO2 30; infusion 110; tracheostomy tubes 10 100; gauzeZ2000; paediatric oxygen therapy 10; Cystofix 10; intubation 6/7 at 50 each; Guedel 2 kits; gel 11 ml 50; ultrasound500 ml 1A14, A15REQUIRES PARTNER / NO-BID to complete
Partial sourcing; full 18 lines or equivalence not confirmed. Clarification required on Cystofix unit ' 120m' and gauze packaging 12 cm×3,75.
35. Electrocardiograph
Diagnostic equipment
4 units; 3 channels, 5″800×480 screen, Glasgow, 12-lead+Cabrera, 80 mm paper, 800 memory, PDF/USBA03WORTH PREPARING once delivery and compliance are confirmed
Mindray BeneHeart R3 is a well-matched reference model, but current sprzedaży/produkcji status and exact configuration must be confirmed; the current product page does not prove stock availability.
37. Ventilator and accessories
Ventilators and parts
4 UNI VENT EAGLE754CE-type ventilators; WM36333×1; MEDUMAT Standard A test lung×1; Hersill Vitae 40 single-use circuit×2 and reusable×2; WM22520×1A07REQUIRES PARTNER / NO-BID to confirm legacy equipment and all parts
The basket includes different systems. Hersill channel / reusable circuit confirmed, but not the specific WM36333/WM22520 or new EAGLE754CE. Do not substitute the newer ZVent without an equivalence matrix.
38. Oxygen therapy and anaesthesia
Respiratory products
21 lines; filters 30+40; M2 1005; MEDUVENT masks S/M/L at 1 each; CPR300; O2XL120; nebulisation 40; O2 with bag 60; AEROBAG30 kits; LTS-D sizes 5/4/3/2 at 50,1/0 at 20; LMA5 13; NPA6,5 1000 and 7,0 400; stabilisers 100A06, A14, A21REQUIRES PARTNER / NO-BID for full completion
LTS-D is precisely identified. The remaining lines have gaps materiałowe/kompatybilności; MEDUVENT masks are not generic masks. The full basket is not certified.
43. Glucose meter and accessories
IVD diagnostics
Instant 5; Active strips 5×50; ' Glucicard' 1×50; single-use lancets 50; FastClix with lancets 8×24A05REQUIRES PARTNER / NO-BID to clarify the strips
Instant and Active are separate systems; do not assume compatibility. ' Glucicard' has not been conclusively identified – nazwa/model/SKU. is required. FastClix set a 24 not confirmed.
44. Gas
Gas and tool
1 gas to refill the torch +1 gas torchNo compatible source identified; gap.NO-BID to clarify the specification
Gas type, capacity, connection, model and torch application not specified. No arbitrary OEM has been added.
47. Stretchers and accessories
Evacuation equipment
FOXTROT4; SKED4; aluminium typeB1 kits; winter stretcher with insulation and hood 3; scoop stretchers 1; Toboggan with equipment 3A07, A08, A09, A10REQUIRES PARTNER / NO-BID to complete 6 lines
Sources FOXTROT/SKED and scoop stretchers confirmed. No reliable match for typeB, winter stretchers or a complete Toboggan. FOXTROT weight≤2,5 kg to be confirmed.
48. Artificial blood
Simulation materials
40 units; 25 ml, simulation powderA08NO-BID to clarify capacity
BLD-04S is a genuine powder, but its product sheet specifies 4,4oz, not 25 ml. This is only a channel for enquiring about the correct product, NOT a compliant substitute. Establish whether 25 ml refers to proszku/opakowania/roztworu and confirm compatibility with manikins.
49. Chair
Medical furniture
2 blood and plasma collection chairsA16, A17WORTH PREPARING once the intended use is clarified
JuventasJFK2 and Promotal Deneo are actual blood collection chairs; their suitability for a prolonged plasma collection procedure or the required configuration has not been confirmed.
50. Simulated pulse oximeter
Medical simulation
2 Bluetooth training devices; Windows/Mac/Android/iPad; dongle, charger, case and instrukcjaPL/CDA01, A02WORTH PREPARING with a complete configuration
OXI02/SYMH: Oxi is functionally suitable; the current OEM standard includes Oxi+cable+notice, not the entire required set. Confirm the dongle, case, charger and documentation PL/CD. This is a simulator, not a clinical pulse oximeter.
51. Blood typing kit
IVD diagnostics
2 kit units as per the procurement specifications; reagents 10 ml, composition and number of reagents not specifiedNo compatible source identified; gap.NO-BID for full identification
No antygenów/odczynników, method or compatible analyser specified. No arbitrary OEM or teaching kit has been assigned.
53. Flow-through sets
Materials for a warmer
48 single-use One Buddy Disposable SetA08, A12WORTH PREPARING once REF and the Polish sales channel are confirmed
Belmont buddyDisposable 905-00010 is a real item, but the name One Buddy requires model confirmation ogrzewacza/REF.48 units correspond to 2×24 according to the catalogue; the order MOQ has not been confirmed for Poland.
55. CO2 indicator
Respiratory products
203 single-use CO2 indicatorsA19, A20WORTH PREPARING once the variant is clarified
Two actual kanałyPL/USA, but the patient population and target złączy/typu. have not been specified. ALL-EASYCAP-II has not been deemed automatically identical to Nellcor/Medtronic; interchangeability of Mercury variants is not claimed.
56. Infusion pump
Infusion equipment
6 syringe pumps; IEC60601, touchscreen, 2/5/10/20/50/60 ml syringes (listed with commas in the procurement specifications), 30 h battery, charging time ≤5 h, alarms in PolishA04WORTH PREPARING with the OEM
Medima S100/S200/S300 has the appropriate product family and features, but no variant has been identified that meets every requirement 30 h/≤5 h, infusion units and the complete syringe list. A compliance matrix and current certificate are required.
57. ETCO2 hose
Capnography accessories
10 single-use male 7 ft leads for RESPSENSEA13WORTH PREPARING once compatibility and quantity are confirmed
Nonin continues to support sales of accessories (monitors are no longer sold). Current CO2sampleline 5821-000(25 pack); historical Salter instructions 4507. Confirm 7 ft, both connectors and the SKU for the existing model; do not offer the entire monitor.
60. Medical waste containers
Waste equipment and supplies
30 transparent 30l+30 transparent 50l; sharps 500 ml 10/0,7l 10/1l 5/2l 15; red bags 60l 2×50A18, A22REQUIRES PARTNER / NO-BID for full completion
Picadura maps to 0,7/1/2l; APmedical DISPO additionally 500 ml. Transparent 30/50l heat-resistant containers and red bags 60l have still not been matched. The procurement specifications do not state a temperature range. The complete basket is not finalised.
61. Infusion fluid warmer
Medical equipment / heating
2 set — Transport and simultaneous heating of up to 3 l; built-in microcontroller for electric temperature regulation.A07, B01WORTH PREPARING / PARTNER REQUIRED
Confirm the complete set, power supply and whether EMERGO 10.021 is identical to the current Sacci product 111521; do not use chemical 111526 1 l.
62. Kinesiology tapes
Rehabilitation supplies
6 rolls 5 cm×5 m; 5 packs of adhesive 400 ml; 6 packs of rigid blue tapes — Three separate items. For the rigid tape, width, length and number of rolek/opakowanie. are missing.No compatible source identified; gap.NO-BID pending clarification of the adhesive and set contents
A complete compliant basket has not been confirmed. The adhesives identified at 200/237/300 ml do not meet the literal requirement of 400 ml. Do not substitute cooling spray.
63. Crutches
Rehabilitation equipment
23 adult elbow crutches; 20 adult axillary crutches — The unit is one piece, not a pair. User sizes and additional parameters are unspecified.B02WORTH PREPARING FOR
Confirm the adult size and price per individual piece; do not convert 23 pieces into 23 pairs.
65. Bedding, sheets
Disposable medical textiles
50 underpads 50 m×50–60 cm/2 layers; 50 green sheets 160×210; 200 sheets 28 g 80×210 cm; 1 packs «60x80m»; 110 X-ray drapes+tape — Five items; the format «60x80m» is reproduced verbatim and requires clarification. The drape size and number of layers are missing.A14NO-BID pending clarification of sizes and set contents
ZARYS confirms SERVI lux/SERVI lux S with X-ray and tape for item 5 only; a compliant complete basket has not been confirmed.
69. Miscellaneous
Mixed medical equipment and accessories
10 lines: collars 204; urine containers 100 ml 200; T-connector 51390 20; paper bowls 900 ml 100; Schiller paper FT-1 114×150 mm/60 sheets 1 packs; signal devices czerwone/zielone/żółte at 200 each; emesis bags 50; pneumothorax decompression inserts 10 sets — This section includes an option right of 100% under the procurement specifications; the original quantities are stated separately from the option.No compatible source identified; gap.NO-BID pending identification of the 10-line basket
The OEM for the 51390 connector, the type of signal devices and a compatible simulator for the pneumothorax inserts have not been identified. Do not select an arbitrary OEM based on the name alone.
71. Probe
Accessories for medical devices
30 units — Adult tympanic probe for HOPETHERM, memory foam, cover, 36G cable.B03WORTH PREPARING FOR
HOP-HT-SB-1 matches the description. The website states 24 h and a minimum order of 1 units, but does not confirm stock of 30 units. Confirm the specific batch and expiry date.
72. Electric suction apparatus
Medical equipment / suction units
8 set — Glass overflow container 0,25 l, four-castor stand with brakes, 2 l container, 1,5 m/70 cm tubes with MSF/28 cm filter, cylinder switch L/P and clamp.No compatible source identified; gap.NO-BID pending model identification
The exact model and configuration have not been confirmed. A standard portable suction unit 1 l has not been considered compliant with the 2 l set on a stand.
74. Thermometer
Diagnostics / temperature measurement
3 ear thermometers; 1 water thermometers — Ear thermometer with probe positioning control, heated głowicą/czujnikiem, disposable probe covers. Water thermometer with no range or accuracy specified.No compatible source identified; gap.NO-BID pending configuration and clarification
A complete two-item basket has not been confirmed. Similarity to Braun PRO6000 must not be treated as approved equivalence.
77. Analyser
Laboratory equipment
2 units — Title says “haematology”, but the description includes albumin, ALT, amylase, bilirubin, cholesterol, glucose and other biochemical analytes; software in Polish.No compatible source identified; gap.NO-BID pending correction of the procurement specifications
The device class is inconsistent. Without clarification, do not select either a haematology or biochemical analyser, and do not name an arbitrary OEM.
78. Heart and blood pressure monitoring device
Cardiac diagnostics
7 units — 24 h RR, ST and HRV, and 2-channel ECG strips; event-triggered recordings and patient button.B04NO-BID to confirm the current model
The description points to the legacy CardioTens. The OEM describes its successor, card(X)plore, with 3 channels. Current availability of the old model and equivalence of its successor have not been confirmed.
79. Resuscitator
Medical emergency response / resuscitation
12 set(s) — Resuscitator with mask No.5, mask No.3, 5 filters, suction device Res-Q-Vac, 6 tubes ustno-gardłowych, bag.No compatible source identified; gap.NO-BID to complete the set
No current legal supply channel has been confirmed for the exact Res-Q-Vac suction device and complete set. It has not been replaced with an arbitrary suction device.
80. Autoclave
Sterilisation / medical equipment
1 set(s) — EN13060; 17 l; 240 V/50 Hz; 2–2,4 kW; max500×450×600 mm; chamber195×195×312 mm; 3 tacki/stelaż; USB; tanks≥2 l.No compatible source identified; gap.NO-BID to confirm model / tolerances
No fully compliant model was found. The W&H Lara checked measures 465×452×646 mm, exceeding the limit szerokości/głębokości; it is not presented as a compliant source.
83. Patient monitor
Medical monitoring
2 set(s) — Adults and newborns, HRV/EKG/SpO2, mains + battery, cuffs, SpO2, RJ45, CD/DVD with software, transport case.No compatible source identified; gap.NO-BID for the compliance matrix
No specific model meeting all requirements, including software and accessories, has been confirmed. A monitor family alone does not constitute complete compliance.
84. Furniture
Medical furniture
2 examination couches; 4 folding tables50×100 cm; 6 tables50×50 cm; 10 metal screw-mounted stools — Examination couch min1850×550×500 mm, load capacity200 kg, headrest -80°/+45°, roll holder.No compatible source identified; gap.NO-BID to clarify and complete
A complete set has not been confirmed; the unusual -80° headrest angle needs checking and must not be changed without authorisation to -8°/-15°.
85. Lamps
Medical equipment / lamps
3 airflow lamps UV-C; 4 lamps described as LED on a stand — Item1 acid-resistant housing, airflow UV-C in the presence of people. Item2 is called bactericidal, but has LED3×10W,4750/5000K, gooseneck,92 cm, stand95–130 cm.B05NO-BID to clarify item2
There is an explicit contradiction in item2: visible-light specifications do not confirm a bactericidal function. NBVE is a candidate only for item1; the type of obudowy/dokładny variant requires a compliance matrix.
87. Vacuum mattress
Emergency response / immobilisation
2 units — 115×205 cm; folded60×85×23 cm; 6 handles; hook-and-loop straps; red PVC; pump with 120 cm hose and bag.A07NO-BID for a compliant variant
The actual REDVAC VM8021E1X01 product sheet specifies 8 handles and quick-release straps, not literal 6/hook-and-loop straps. A channel to enquire about the correct variant, not a ready-made compliant product.
88. Stand
Medical equipment / infusion
26 units — Folding stand for wlewów/kroplówek; metal tube with straps for securing a container; cover optional.No compatible source identified; gap.NO-BID to identify the design
No portable model with exactly the described fastening has been identified. It has not been replaced with a bedside wheeled stand.
89. Patient transport trolley
Furniture / patient transport
2 units — 210×69 cm; lying surface195×62; hydraulic height46–85 cm; backrest45°; wheels125 mm with directional lock; load capacity240 kg; ~80 kg.B06WORTH PREPARING / PARTNER REQUIRED
The E-2 product sheet matches the main dimensions and functions. Confirm that the mattress, hanger, oxygen cylinder basket and rails are included, as well as producenta/dokumenty.
90. CPR training set
Physical training aids
6 set(s) — Adult torso, Ambu hygiene system, BLS and ACD CPR, 5 face pieces,50 bags and bag.B07NO-BID to select ACD and accessories
The current AmbuMan BasicA268012000 includes1 face piece and25bags; ACD not confirmed. The standard Basic set has not been deemed compliant.
91. LC set — incubator
Laboratory equipment
2 set(s) — Incubation of media with samples, digital temperature control, shelf for fiolki/płytki, open-door indication.B08WORTH PREPARING FOR
CLW15 has a PID controller, shelves and door indication. The required pojemności/zakresu is missing from the procurement description — confirm usable capacity of 14 l and acceptance of the configuration.
92. LL set — refrigerator
Physical equipment / refrigeration
1 units — Laboratory: universal refrigerator for220 V,12 V and gas; no capacity or cooling range specified.B09, B10MONITOR / NO-BID pending temperature requirements
ACX3 40 is an actual absorpcyjnym12/230V/gaz device, but its suitability for laboratory use stabilności/zakresu has not been confirmed, nor has acceptance of 230V instead of the literal 220V and the correct gas variant.

How to prepare to participate — 31 WOG

Confirmed in the historical procurement specifications: Article 132, offer in Polish with a qualified electronic signature, option to bid for one or more lots, each evaluated separately. Bid and price forms, ESPD, sanctions and representation; upon request, Criminal Records Register certificate ≤6 months, up-to-date ESPD and information on the capital group. No tender security, performance bond or special threshold of obrotu/referencji in the common conditions. Evidence of equivalence must be submitted with the offer and cannot be supplemented later. Each line must have producenta/przedstawiciela/importera and model/SKU identifiable on the official website. An incomplete line may result in rejection of the entire lot.

New goods, manufactured in 2025–2026, with ≥80% of total shelf life remaining for dated products. Delivery within 14–45 days of the contract, price 90% / delivery time 10%; the delivery-time evaluation text is ambiguous and needs clarification. One-off delivery to the medical warehouse in Zgierz; transport and unloading by the contractor; notification 2 working days in advance; representative present; acceptance by signed report. Payment within 30 days; as a rule, 2 years’ warranty unless OPZ/ważność provides otherwise. The WET of lots 1–8 and 76 does not cover any of the 39 current lots. We do not impose a clinical MDR/CE on every training manikin solely by virtue of the procurement.

Commercial barriers: the draft contract provides for a penalty of 10% of the gross value of the late goods for each day of delay, a penalty cap of 30% of the contract value, and the possibility of claiming additional damages. The procurement specifications also contain a restriction on products above 10 000 PLN gross — the interpretation of sets and whether it remains current in a new tender need clarification. This is not a disclosed net estimate. OEM authorisation, a military concession, AQAP, NSN or EUC have not been added as automatic conditions.

What to do now — practical conclusions, not additional conditions

  1. Identify the new formal tender and lot mapping; do not submit a bid to the closed 1315032.
  2. Build a matrix for each line using the full price list and clarifications. Separate clinical products from training products; clarify INSTANT/ACTIVE/Glucicard, the analyser77, the lamp85 and the incorrect units120m and60×80m.
  3. Confirm the exact SKU, every parameter, Polish documentation and equivalence through the appropriate OEM/PL channel. For variants and substitutes, a product family name is not enough.
  4. Obtain written zapas/termin, production date, shelf life and warranty; calculate 14–45 days, option only69, unloading, financing and exposure to penalties.
  5. Prepare all forms, ESPD, sanctions, representation and product evidence; before submitting a new offer, clarify the limit of10 thousand PLN and the delivery-time scoring.
  6. Only after the new tender opens and full compliance is established should you sign the qualification, submit via the correct platform and retain confirmation. If gaps remain unresolved: NO-BID.

Recommended structure: specialist medyczny/symulacyjny or multi-OEM integrator; direct OEM also possible. Partner/konsorcjum is a commercial inference, not an unconfirmed SWZ requirement. The historical transaction card looped on public SSO; the working ZIP contains the SWZ and price schedule. We do not certify that we have read inaccessible new notices or that changes across the entire portfolio are complete.

How to prepare to participate — WIM, lot 16 / LOT-0017

Confirmed basket: 36 training chairs: 18 for USK Białystok, M. C. Skłodowskiej 24a, and 18 for USK4 Lublin, Dra K. Jaczewskiego 8. Backrest, folding writing tablet integrated with the frame, metal frame płasko-owalna, non-slip feet and load capacity of at least 110 kg. New and complete goods. This is standard training furniture, not a medical chair or evacuation chair.

Historical requirements: maximum 8 weeks from the contract, price 100%, no bid bond or performance bond, no special obrotu/referencji conditions and no subject-matter evidence in the SWZ reviewed. Tender in Polish, qualified electronic signature, ESPD, sanctions, formularz/cennik and representation; upon request, National Criminal Register certificates issued within the last 6 months, group of companies statement and up-to-date ESPD. The relevant eB2B card leads to rejestracji/składania, but the historical tender is closed. Contact in the SWZ: Elżbieta Buźniak, communication via the platform; central e-mail and telephone number in the table.

Delivery to both hospitals at the contractor's cost and risk, on business days 8–14 by arrangement, with separate acceptance reports and invoices. Payment within 60 days via KSeF; warranty of at least 24 months or longer if offered by the OEM. No concession, AQAP, NSN or EUC requirements have been added for chairs as a default.

Significant history: notice 08.09 expressly reissued the former lots 16/20 as 110/ZP/26; the chair became lot 1 there. The deadline of 12.10.2026 at 10:00 has passed. The opening information confirms 3 bids for the chairs. This is not a new zero-bid result or an active opportunity; the final outcome of 110 has not been confirmed. Evidence of formal reissue · Opening 110 — three bids · Full SWZ and attachments 74, technical description p. 30.

What to do now — practical recommendation

  1. Check the outcome of 110, lot 1, and further purchases; do not bid in the closed 74 or 110.
  2. Build a matrix of five parameters, quantity of 36 units and two delivery addresses.
  3. Obtain from the OEM the exact configuration code and evidence of the frame profile, folding integrated writing tablet, load capacity of ≥110 kg and non-slip feet. A photo alone is not sufficient.
  4. Calculate the cost of two deliveries, a warranty of at least 24 months and financing for 60 days; prepare Polish-language documents and a qualified electronic signature.
  5. Only in the event of a new active tender, verify the SWZ and deadline. Without full compliance: NO-BID.

Assessment: MONITOR the outcome / NO-BID without a new tender and full compliance. Direct OEM or furniture supplier; a local kanał/UE is a logistics recommendation, not a mandatory authorization.

Where to buy the chairs — two actual OEMs, not confirmed substitutes

W1 · Nowy Styl sp. z o.o. — Poland · OEM

Candidate: Iso, four legs, backrest and factory option of a writing tablet. The official catalogue confirms the category and available equipment; the exact folding version, profile płasko-owalnego, non-slip properties or load capacity of 110 kg in this configuration have not been confirmed.

Contact: central, +48 13 437 61 00; no named sales representative identified. The manufacturer's own product line on its website is evidence of its OEM role, not a basis for assuming that an intermediary needs authorization.

Iso · Configurations with a writing tablet · PL contact · Official e-mail / contact.

W2 · Leyform srl — Italy · OEM

Candidate: Sally, four legs + 68812 option, folding ABS writing tablet. The official catalogue specifies an oval steel frame measuring 30 × 15 mm and PE feet. Not confirmed load capacity ≥110 kg, non-slip properties of the feet, or literal profile płasko-owalnego.. Norma EN 16139 has not been automatically converted into a load capacity.

Contact: , +39 0438 430050, published in the official listing; osoby/stanowiska not provided. Sally and writing tablet · Manufacturer specifications and data · Official contact channel.

For both OEMs, stock of 36 units, MOQ, lead time, deliveries 18+18, warranty for the specific configuration and export terms have not been confirmed. RFQ — not sent: Does the exact configuration meet all five parameters, including płasko-owalną frame, non-slip feet and 110 kg? Please provide the code, written compliance matrix, documents, price netto/VAT, availability, MOQ and timing for two deliveries, warranty of at least 24 months, sprzedaży/odsprzedaży terms for Poland and any export restrictions.

Where to buy — mapping to lots

Shared caveat: these are verified channels and specific product candidates, not ready-made bids. Unless explicit evidence is indicated below, availability of the required quantity, stock status, MOQ, lead time, sales territory, batch validity, warranty, authorization and export-related warunki/zgody have not been verified not confirmed. Contact does not prove authorization or product compliance. No RFQ was sent and no forms were completed.

A01 · Simedu Sp. z o.o. — Poland

Role: Authorized distributor of Innov 2 Learn (the OEM locator lists Poland and logo/link Simedu)

Product / mapping: SYMH:Oxi – Innov 2 Learn simulated pulse oximeter

Parts / items: Part 50:2 units

Fit: Bluetooth, all listed OS, manikins and any types of fingers; complete equipment must be confirmed by RFQ.

Status evidence: The listing describes the company as a direct distributor; the OEM locator confirms Simedu for Poland.

Contact: Paulina Zawadzka – Public Procurement Specialist

E-mail:

Telephone: +48 781 600 861

Availability: Made to order; 2 units or lead time not confirmed.

Commercial inquiry — prepared, not sent: Please quote 2OXI with dongle Windows/Mac, EU charger, case and PL/CD manual; confirm full technical description, warranty, lead time and authorization.

Product · Contact 1 · Contact 2

A02 · Innov 2 Learn — Canada

Role: OEM

Product / mapping: Oxi OXI02

Parts / items: Part 50

Fit: Actual SpO2/tętna simulator, BLE; the basic set does not prove etui/dongle/PL.

Status evidence: OEM's own product listing and partner locator.

Contact: Central sales; named sales representative not confirmed

E-mail:

Telephone: +1 877 807 1676; +1 514 544 0479 (SMS)

Availability: Stock of 2 units and delivery to Poland not confirmed.

Commercial inquiry — prepared, not sent: Please confirm OXI02 and complete configuration 31 WOG, delivery via Simedu, warranty, Polish-language documentation and export terms.

Product · Contact

A03 · Mindray Medical Poland / Shenzhen Mindray — Poland / China

Role: Local OEM office / OEM

Product / mapping: BeneHeart R3

Parts / items: Part 35:4 units

Fit: Glasgow, 5″ screen, 3 channels and 80 mm paper; full matrix, including 800 entries, to be signed off by the OEM.

Status evidence: Official Polish listing and official office directory.

Contact: Sales Poland; named contact not published

E-mail: ;

Telephone: +48 22 463 80 80; +86 755 8188 8997

Availability: Current production, stock and lead time for 4 units not confirmed.

Commercial inquiry — prepared, not sent: Can you supply 4 new R3 units meeting every point of the technical description? Confirm production status, PDF/USB/Cabrera/800zapisów, Polish-language documentation, service, price and lead time.

Product · Contact

A04 · MEDIMA Sp. z o.o. — Poland

Role: OEM – pump manufacturer

Product / mapping: Syringe pump family S100/S200/S300

Parts / items: Part 56:6 units, model selection not finalized

Fit: Color touchscreen and automatic syringe installation; details of 30 h/≤5 h and all capacities to be confirmed.

Status evidence: Current product page and contact details on the manufacturer's own website.

Contact: Anna Krawczyk – Senior Public Procurement Specialist

E-mail:

Telephone: +48 534 579 188; switchboard +48 22 313 22 66

Availability: Specific model, 6 units and lead time not confirmed.

Commercial inquiry — prepared, not sent: Please select a model of 6 pumps with a full technical-description compliance matrix, 30 h pracy/ładowanie≤5 h, IEC60601, Polish-language alarms, price, lead time and warranty.

Product · Contact

A05 · Roche Diagnostics Polska Sp. z o.o. — Poland (OEM channel)

Role: Manufacturer’s own Polish channel

Product / mapping: Accu-Chek Instant; Active strips; FastClix

Parts / items: Lot 43 lines 1/2/5; not Glucicard

Fit: The correct genuine product families, without conflating Instant and Active.

Status evidence: Official Accu-Chek product sheets and Roche contact.

Contact: Central customer service Accu-Chek; no named contact confirmed

E-mail:

Telephone: 801 080 104; switchboard+48 22 481 55 55

Availability: FastClix ilości/partii/opakowania 24 not confirmed.

Commercial inquiry — prepared, not sent: Please confirm dokładneSKU/ilości Instant, Active 50 and FastClix with 24 lancets, expiry date and price. Do not substitute Instant strips for Active strips.

Product 1 · Product 2 · Product 3 · Contact

A06 · VBM Medizintechnik GmbH — Germany

Role: OEM

Product / mapping: Quicktrach II4 mm with cuff; Laryngeal Tube LTS-D

Parts / items: Lot 21 Quicktrach line 20; lot 38 LTS-D sizes 0–5 (240 units)

Fit: Quicktrach II is an adult 4 mm tube with cuff; the I version without a cuff is not an automatic substitute. LTS-Ddobór syringe included, as specified in the procurement specifications.

Status evidence: Own OEM product sheets.

Contact: Sales Department; no named contact confirmed

E-mail:

Telephone: +49 7454 9596-50

Availability: Polish documentation and lead time not confirmed ilości/partii/kanału.

Commercial inquiry — prepared, not sent: Please provide 20 Quicktrach II4 mm in a tube iLTS-D0/1po 20,2/3/4/5after 50 with a syringe; Polish conformity cards, expiry date, price, channel in Poland, and delivery.

Product 1 · Product 2 · Contact

A07 · Paramedica Polska Sp. z o.o. Sp.k. — Poland

Role: Specialist supplier; authorization for the specific product not confirmed

Product / mapping: Adult QUICKTRACH; Hersill Vitae 40 with reusable circuit; aluminum scoop stretcher with 3 straps; EMERGO3l model10.021/SKU PP-0173; REDVACVM8021E1X01/PP-0143

Parts / items: Lot 21 partially; 37 Hersill / circuit only; 47 item 5; 61:2 set; 87: channel for selecting a compliant variant only

Fit: Genuine new product sheets following the WP migration. Confirm Quicktrach II with cuff, the Vitae 40 circuit alone, without purchasing the ventilator, and the stretcher SKU. 61: current product sheet confirms 3×1l and microcontroller 37±2°C. 87: product sheet confirms PVC+pump+bag, ale8uchwytów/szybkozłącza nie6/rzepy.

Gaps: Current authorization from Sacci/Kohlbrat & Bunz for this delivery, or full compliance with 87, not confirmed.

Status evidence: Current catalogue sheets that are live.

Contact: Emergency Medical Services Market Department

E-mail:

Telephone: +48 22 313 09 39

Availability: Quantity, exact OEM parts and lead times not confirmed.

Commercial inquiry — prepared, not sent: Please quote the correct separate items for 31 WOG with REF, compatibility and an authorized OEM channel, warranty and lead time; not complete devices instead of accessories. Please provide the net price and realistic lead time for 2 EMERGO3l set, and specify a 115×205 cm mattress, 6uchwytów/rzepy, red PVC, pump+hose 120 cm+bag for 2 units. Please provide exact SKU, compatibility matrix, OEM channel authorization, warranty, Polish documentation, quality, MOQ and terms dostawy/eksportu.

Product 1 · Product 2 · Product 3 · Product 4 · Product 5 · Contact

A08 · J. Posmyk Mil-Sys Sp.K. (ParaMedica MIL-SYS) — Poland

Role: Specialist supplier; OEM authorization not certified

Product / mapping: SKED Basic Rescue SystemSK-200C-GR; Belmont Buddy Lite and cartridges; artificial krewBLD-04 powder

Parts / items: Lot 47 item 2; 53 potential channel; 48 partial match

Fit: A separate company from Paramedica Polska. Exact 905-00010 insert not confirmed; BLD-04S is 4,4 oz, so it has NOT been matched to the required 25 ml.

Status evidence: Own live product sheets and sales information.

Contact: Central sales channel; no named contact confirmed

E-mail:

Telephone: +48 662 721 408

Availability: ilości/terminu/25 ml or specific authorization not confirmed.

Commercial inquiry — prepared, not sent: Confirm 4 SKED with full accessories, 48 correct Buddy cartridges and possible blood 25 ml; compliance matrix, OEM/REF, price, warranty and lead time.

Product 1 · Product 2 · Product 3 · Contact

A09 · Skedco, Inc. — USA

Role: OEM

Product / mapping: SK-200/SK-200C-GR Basic Rescue System

Parts / items: Lot 47 item 2:4 units.

Fit: OEM confirms Cordura, helicopter-lift / vertical-lifting harnesses and complete set. 17 lb≈7,7 kg, within the 5–10 kg specified in the procurement specifications; confirm final configuration.

Status evidence: Own product sheet and distributor locator.

Contact: Head office; no named sales representative confirmed

E-mail:

Telephone: +1 503 691 7909

Availability: Direct online sales only in the continental US; international channel for Poland. Authorization for Mil-Sys. not confirmed

Commercial inquiry — prepared, not sent: Please confirm 4 kompletneSK-200GR for Poland, an authorized channel, complete accessories as specified in the procurement specifications, price, warranty and any export restrictions.

Product · Contact

A10 · TacMed Solutions — USA

Role: OEM

Product / mapping: Foxtrot DA with Carrier F-LITC-DA-T

Parts / items: Lot 47 item 1:4 units.

Fit: A genuine Foxtrot with cover, suitable for dragging and carrying; weight ≤2,5 kg and full compliance require confirmation.

Status evidence: Own product sheet and sales department.

Contact: TacMed Medical; no named contact confirmed

E-mail:

Telephone: +1 864 224 0081

Availability: Stock of 4 units, channel in Poland and export not confirmed.

Commercial inquiry — prepared, not sent: Does 4 Foxtrot DA with cover meet ≤2,5 kg and the full procurement specifications? Please provide REF, price, delivery to Poland, warranty and dokumenty/eksport.

Product · Contact

A11 · Masimo Polska / Masimo International — Poland / Switzerland / OEM USA

Role: Manufacturer’s own local and regional OEM channel

Product / mapping: EMMA Airway Adapter PN17448adult/pediatric (25 box) or 17449 infant (10 box)

Parts / items: Lot 27 item 2:2 units.

Fit: Genuine adapter; intended patient population and 2 units versus commercial pack size need clarification. Does not cover Pin Index.

Status evidence: Official product sheet and global contact locator.

Contact: Mariusz Jamka – Poland contact in OEM locator (no additional position given)

E-mail:

Telephone: +48 510 036 367

Availability: 2 units, MOQ for pack splitting and lead time not confirmed.

Commercial inquiry — prepared, not sent: Select an EMMA adapter for the existing urządzenia/populacji, potwierdzićREF17448/17449, and confirm the possibility of supplying 2 units, price, expiry, documentation and lead time.

Product · Contact

A12 · Belmont Medical Technologies — USA / regional channel in Germany

Role: OEM

Product / mapping: buddy Disposable Set 905-00010

Parts / items: Lot 53:48 inserts (catalogue 24/box)

Fit: Correct warmer product family; confirm the name of the existing One Buddy/REF device before submitting an offer.

Status evidence: Official precise catalogue and contact.

Contact: Military Inquiries / Sales

E-mail: ; ;

Telephone: +1 978 663 0212; Germany+49 221 65084876

Availability: 48 szt/terminu delivery to Poland not confirmed; a public general banner stating “disposables in stock” does not confirm this order.

Commercial inquiry — prepared, not sent: Please confirm 905-00010 for the existing One Buddy, 48 units, pack size, batch and expiry, price in Poland, OEM channel and export.

Product · Contact

A13 · Nonin Medical, Inc. / Nonin Medical B.V. — USA / Netherlands

Role: OEM / own regional office

Product / mapping: CO2 Sample Line 5821-000 (25 pack); legacy Salter 4507 in the RespSense II manual

Parts / items: Lot 57:10 male 7 ft tubing

Fit: The OEM continues to support capnography accessories despite discontinuing sales of the monitors. Confirm current REF, 7 ft and connectors.

Status evidence: Current technology page contains an accessories table; RespSense support specifies 7 ft.

Contact: Customer Support; no named contact confirmed

E-mail: (official general channel)

Telephone: +1 763 553 9968

Availability: 10 units, splitting of the 25 pack and delivery to Poland not confirmed.

Commercial inquiry — prepared, not sent: Please provide the current SKU for 7 ft tubing, male-male for the specified RespSense, 10 units, pack MOQ, expiry, price, documentation and delivery to Poland.

Product 1 · Product 2 · Contact

A14 · ZARYS International Sp. z o.o. — Poland

Role: Producent/własna brand and specialist supplier

Product / mapping: SERVIlux / SERVIluxS – X-ray-detectable drapes with thread and tie tape; remaining basket still to be selected; SERVI lux / SERVI lux S with X-ray-detectable thread and tie tape

Parts / items: Part 21 napkin 45×45×100 pcs.; potential completion 29/38 without confirmation of all lines; 65 item only5; other lines not certified4

Fit: A real X-ray series, but the exact SKU45×45 and sterylność/opakowanie require confirmation. The entire lot is not certified.; The official catalogue confirms multilayer surgical drapes with X-ray thread and tape.

Gaps: Not specified: rozmiaru/warstw/sterylności 110 pcs. The full lot or the «60x80m» format has not been confirmed.

Status evidence: Official wound-care materials page and contact.

Contact: Aleksandra Stelmaszczyk – Customer Service, hospital market, Łódzkie Voivodeship

E-mail: ;

Telephone: +48 32 555 03 64; +48 32 271 69 91

Availability: Not confirmed: 100 pcs 45×45 or the complete baskets.

Commercial inquiry — prepared, not sent: Please provide SKU45×45 X-ray thread with tape and 100 pcs, and a list of only the coverable items 29/38, conformity documents, prices, lead times and validity.; Once the specifications have been clarified, please indicate the SKU 110 for X-ray drapes with tape in the correct size, number of layers and sterility, and whether the remaining 4 lines of lot 65 can be completed. Please provide prices, stock status, MOQ, lead time, warranty and documentation jakości/PL.

Product · Contact

A15 · B. Braun / Aesculap Chifa Sp. z o.o. — Poland / German OEM group

Role: Manufacturer’s own local channel

Product / mapping: Cystofix Punction Set J Ready-to-use

Parts / items: Part 21 Cystofix×10; part 29 Cystofix×10

Fit: The correct suprapubic product family. Exact REF 3,6 mm/CH10 and markers 90/130/190 require confirmation; do not transfer data from the veterinary catalogue.

Status evidence: Official current PL catalogue and contactPL.

Contact: Head office / sales office in Warsaw; no named contact confirmed

E-mail:

Telephone: +48 61 442 01 00; sales office Warsaw+48 22 590 71 80

Availability: Not confirmed: 20 pcs, REF, MOQ or lead time.

Commercial inquiry — prepared, not sent: Please provide the correct Cystofix REF 3,6 mm/CH10 with the required markers and quantity of 20 pcs; clarify the 120m needle unit in the specifications, and confirm PL documents, price and lead time.

Product · Contact

A16 · Ziółkowski Juventas S.K.A. — Poland

Role: OEM / medical furniture manufacturer

Product / mapping: JFK2 blood-draw chair

Parts / items: Part 49:2 pcs, candidate requiring clarification of plasma use

Fit: Manufacturer’s own blood-draw chair with adjustable backrest and armrests; dedicated use for plasmapheresis has not been confirmed.

Status evidence: Manufacturer’s own product sheet and sales department.

Contact: Sales department; no named sales representative confirmed

E-mail:

Telephone: +48 13 463 80 35; +48 608 074 052

Availability: Not confirmed: 2 pcs or lead time for this order.

Commercial inquiry — prepared, not sent: Is the JFK2 also intended for plasma collection in accordance with the requirements of 31 WOG? Please provide a declaration of intended use, configuration for 2 pcs, price, lead time and warranty.

Product · Contact

A17 · Promotal SAS — France

Role: OEM / medical furniture manufacturer

Product / mapping: Deneo blood sampling & vaccination chair, 800XX-XX family

Parts / items: Part 49:2 pcs, candidate subject to clarification of plasma use

Fit: A genuine 200 kg blood-draw chair with an emergency position; use for collecting osocza/konfiguracji. has not been certified

Status evidence: Manufacturer’s own product sheet and official Export-Lib contact.

Contact: Export-Lib; address published without expansion of nazwiska/stanowiska

E-mail:

Telephone: +33 2 43 05 68 95

Availability: Product sheet: delivery “nous consulter”; 2 szt/leadtimePL. not confirmed

Commercial inquiry — prepared, not sent: Please indicate the Deneo variant intended for blood and plasma collection, 2 pcs, full configuration, documents PL/UE, Polish sales channel, price, lead time and warranty.

Product · Contact

A18 · Paszek Tworzywa – Picadura — Poland

Role: OEM / container manufacturer

Product / mapping: Picadura sharps 0,7l/1l/2l

Parts / items: Part 21 containers 1l×25; part 60 lines 0,7l×10/1l×5/2l×15

Fit: Domestic manufacture and exact capacities confirmed; does not cover 500 ml, transparent 30/50l containers or 60l bags.

Status evidence: Manufacturer’s official offer and contact.

Contact: Aleksandra Paszek-Łachut – contact published without job title

E-mail:

Telephone: +48 512 130 696

Availability: Quantities, colours, Moq/termindostawy. not confirmed

Commercial inquiry — prepared, not sent: Please quote 0,7l 10 szt/1l 30 szt/2l 15 pcs meeting the specifications; confirm colour, certification and labels, single-use status, price, MOQ and lead time. Do you have 500 ml and separate transparent 30/50l containers suitable for the required temperature?

Product · Contact

A19 · AdMed Medical Partner s.c. — Poland

Role: Specialist supplier; OEM authorization not confirmed

Product / mapping: CO2 ALL-EASYCAP-II detector, SKU21370

Parts / items: Part 55:203 pcs, typ/populacja to be confirmed

Fit: A genuine single-use colorimetric detector with a 15 mm connector. It has not been identified as a specific Nellcor/Medtronic, nor has OEM status been inferred from the SKU name.

Status evidence: Seller’s own product sheet and official contact.

Contact: Sales Department; no named contact confirmed

E-mail: ;

Telephone: +48 62 751 24 02; +48 62 307 06 66

Availability: Product sheet states ‘Availability: yes’, but 203 szt/partii/terminu. are not confirmed

Commercial inquiry — prepared, not sent: Please quote 203 single-use CO2 detectors: actual producent/REF, patient population, operating time, connectors, PL documents, expiry dates, availability of the required quantity, price and lead time.

Product · Contact

A20 · Mercury Medical — USA

Role: OEM

Product / mapping: StatCO2 1055370 (> 15 kg); MiniStatCO2 1055371 (1–15 kg); NeoStatCO2 1055373 (0,25–6 kg), 20/box

Parts / items: Part 55: select a specific variant once the patient population has been clarified

Fit: Genuine single-use exhaled CO2 indicators; interchangeability with adult/pediatric/neonatal. is not declared

Status evidence: Official product sheet with product numbers and international sales channel.

Contact: International Customer Service; no named contact confirmed

E-mail:

Telephone: +1 727 573 0088 ext. 3032

Availability: Availability depends on region; Polish sales channel, 203 pcs and pack split 20 not confirmed.

Commercial inquiry — prepared, not sent: Once the patient population has been specified, please provide the correct SKU for 203 pcs, a legal Polish sales channel and conformity documents, price, MOQ, expiry date, lead time and export terms.

Product · Contact

A21 · Laerdal Medical Poland Sp. z o.o. — Poland (OEM’s own office in Norway)

Role: Manufacturer’s local channel

Product / mapping: Laerdal Pocket Mask – variant with oxygen port

Parts / items: Part 38 item 7:300 CPR masks

Fit: Genuine CPR mask family. The correct SKU, filter, valve, case and any ‘replaceable mouthpiece’ must be confirmed; not the training version.

Status evidence: Manufacturer’s own PL product sheet and local office contact.

Contact: Customer Service; no named contact confirmed

E-mail:

Telephone: +48 32 493 70 20

Availability: Not confirmed: 300 pcs or terminu/dokumentów for each variant.

Commercial inquiry — prepared, not sent: Please select SKU300 for CPR masks with an O2 port, one-way valve, filter and durable case; confirm full compliance with the specifications, price, expiry date, PL documents and lead time.

Product · Contact

A22 · APmedical (Keter Italia S.p.A. brand) — Italy

Role: OEM / waste container manufacturer

Product / mapping: DISPO LINE: DISPO 0,5 /0,7 /1 /2

Parts / items: Part 60: candidate for sharps containers 500 ml×10,0,7l×10,1l×5,2l×15; part 21 container 1l×25

Fit: The official product family includes the required capacities and is single-use, puncture-resistant and fitted with a tymczasowym/trwałym. closure. It does not cover transparent 30/50l containers or 60l bags.

Status evidence: DISPO LINE product sheet and Keter Italia contact.

Contact: APmedical central sales; no named contact published

E-mail:

Telephone: +39 0422 745900

Availability: Quantities, colours, MOQ, current PL approvals and lead time not confirmed.

Commercial inquiry — prepared, not sent: Please quote DISPO 0,5l 10 pcs, 0,7l 10 pcs, 1l 30 pcs, 2l 15 pcs with the appropriate kolorem/etykietąPL, documentation and packaging; confirm MOQ, price and delivery time to Poland.

Product · Contact

B01 · Sacci Pro AB — Sweden

Role: OEM

Product / mapping: Infusion Thermo Bag111521

Parts / items: 61

Fit: The current OEM product sheet confirms 3 bags of 1l capacity and software-controlled electric heating at 37±2°C/12V.

Gaps: Confirm that version 111521 is the same as EMERGO10.021 and includes the required components. 111526 is a different 1l chemical warmer — do not map it as equivalent.

Status evidence: Manufacturer’s own product sheet and OEM contact with an address in Borlänge; HTTP200.

Contact: Central wsparcie/sprzedaż; no named contact published

E-mail:

Telephone: +46 (0)243-932 50

Availability: Not confirmed: 2 sets, MOQ or lead time.

Commercial inquiry — prepared, not sent: Is 111521 the correct current equivalent of EMERGO10.021 for 2 sets with 3×1l capacity and a microcontroller? Please provide a compliance matrix, complete set, power supply, PL documents, price, MOQ, lead time, warranty, Polish sales channel and export terms.

Product · Contact

B02 · Timago International Group Ossowski Sp.k. — Poland

Role: OEM identified on its own product pages

Product / mapping: ASSIST-TIM elbow crutch; HandyTim underarm crutch

Parts / items: 63 — both lines

Fit: The product pages confirm the exact types of adult crutches with adjustable height; the price list contains no additional specifications.

Gaps: Confirm sizes and quantities, not pairs. No second OEM was added unnecessarily.

Status evidence: The product pages explicitly identify Timago as the manufacturer; contact details are from the company’s own order department.

Contact: Joanna Kubik — Customer Service Department, Łódzki/kujawsko-pomorski region

E-mail: ;

Telephone: +48 577 123 893; +48 33 499 50 00

Availability: 23+20 units not confirmed

Commercial inquiry — prepared, not sent: Please provide a quote for 23 szt.kulłokciowychASSIST-TIM and 20 adult HandyTim underarm crutches, sizes, quantity cenęnetto/1 units, stock status, MOQ, lead time, Polish conformity documentation, warranty and delivery terms.

Product 1 · Product 2 · Contact

B03 · Internetowe Centrum Dystrybucji Sp. z o.o. — Poland

Role: Specialist supplier; OEM authorization not confirmed

Product / mapping: HOPETHERM HOP-HT-SB-1 probe

Parts / items: 71 — 30 units

Fit: The product page specifies an adult tympanic probe, memory foam, a cover and a 36G cable, OEM Consultronix SA.

Gaps: 30 units and batch validity not confirmed. Contact e-mail was obtained from an official public link on the website (not guessed).

Status evidence: Own product page and official contact, HTTP 200.

Contact: Magdalena Woszczyk — first-aid equipment pomocy/AED

E-mail: ;

Telephone: +48 510 096 571; +48 58 550 50 99

Availability: Product page: 24h, minimum order 1 units; this is not proof of 30 units in stock.

Commercial inquiry — prepared, not sent: Please provide a price and reserve 30 szt.HOP-HT-SB-1, confirm the expiry date, actual stock, shipping lead time, authorization for the Consultronix channel, documents PL/zgodności, MOQ and delivery terms.

Product · Contact

B04 · Meditech Kft. — Hungary

Role: OEM / documentation owner; current legacy channel not confirmed

Product / mapping: CardioTens — historical model; successor: card(X)plore

Parts / items: 78 — clarification of the current model only

Fit: The official OEM history confirms CardioTens 2 channels + RR and the 3-channel successor.

Gaps: Current availability and full conformity of the model currently offered have not been confirmed. The 3-channel models were not presented as automatically conforming to 2-channel requirements.

Status evidence: Official product history and adres/kontaktOEMHTTP200.

Contact: Central sales; no current contact person for this product confirmed

E-mail:

Telephone: +36 1 280 8232; +36 1 280 8233

Availability: Delivery of 7 units of CardioTens not confirmed.

Commercial inquiry — prepared, not sent: Can you supply 7 brand-new CardioTens units, or identify a current product meeting the literal specification for a 2-channel ECG + 24 h RR/ST/HRV? Please provide differences, the required approval of equivalence, Polish-language documents, price, stock status, MOQ, lead time, warranty and the Polish channel.

Product · Contact

B05 · Ultra-Viol sp.j. Pietras, Purgał, Wójcik — Poland

Role: OEM

Product / mapping: NBVE60/30PL — candidate in the przepływowejUV-C family

Parts / items: 85 only, item 1; NOT item 2 LED

Fit: The official product page confirms a mobile lamp with wewnętrznymiUV-C, operating in airflow when people are present and with an external function only when they are absent.

Gaps: Select a version with an entirely przepływowy/obudowę acid-resistant housing and confirm conformity with the specification. Item 2 not confirmed. There is no basis for treating światła4750/5000K as bactericidal.

Status evidence: Official product page and OEM contact, HTTP 200.

Contact: Customer Service Department; no individual contact published

E-mail:

Telephone: +48 42 717 11 76 wew.27/28/29; +48 609 010 717

Availability: 3 units of the appropriate version not confirmed.

Commercial inquiry — prepared, not sent: Please identify 3 mobile lamps with an acid-resistant housing and zamkniętymUV-C, safe for use when people are present, with efficacy test results, a specification compliance matrix, price, lead time, MOQ, warranty and documentation. Item 2 requires prior clarification by the contracting authority.

Product · Contact

B06 · F.H.U. Euro-Medical Maciej Świda — Poland

Role: Specialist supplier; OEM/autoryzacji not confirmed

Product / mapping: Patient transport trolley E-2

Parts / items: 89 — 2 units

Fit: The supplier’s product page confirms 210 × 69 cm, a lying surface of 195 × 62,46–85 cm, a foot pump, wheels 125 mm/blokadęosiową, 240 kg and approximately 80 kg.

Gaps: Before submitting an offer, confirm the exact manufacturer and full set of accessories, including side rails, mattress, oxygen cylinder holder, pole and documents.

Status evidence: Supplier’s product page and contact, HTTP 200.

Contact: Central sales service; the owner’s name does not confirm an individual sales role

E-mail:

Telephone: +48 33 432 25 90; +48 33 444 60 70

Availability: 2 units not confirmed.

Commercial inquiry — prepared, not sent: Please quote 2 szt.E-2 in a configuration meeting the specification, with mattress, side rails, pole and oxygen cylinder holder. Please identify the OEM, provide a compliance matrix, Polish-language product documents, net price, stock status, MOQ, lead time, warranty and delivery to the facility.

Product · Contact

B07 · Ambu A/S — Denmark

Role: OEM

Product / mapping: AmbuMan Basic A268012000 — not confirmed as compliant with ACD

Parts / items: 90 — selection of a compliant version, not a ready-made SKU

Fit: The official product page confirms a BLS torso and a patented hygiene system.

Gaps: The standard A268012000 includes 1 facial part and 25 bags instead of 5/50; ACD CPR has not been confirmed. The Polish CIRRO offer is unavailable, HTTP 503; broken links were not cited as sources.

Status evidence: Current OEM product page and official list of Danish addresses and headquarters consulted on 02.11; HTTP 200.

Contact: OEM head office, for referral to the Polish channel; no named contact for this model confirmed

E-mail:

Telephone: +45 72 25 20 00

Availability: 6 complete sets not confirmed.

Commercial inquiry — prepared, not sent: Please identify 6 Ambu torsos compliant with ACD CPR and the specification, with 5 facial parts, 50 bags and one carrying case each; does the current Basic model have this function, or is another version required? Please provide the SKU, Polish channel, compliance matrix, documents, price, MOQ, lead time and warranty.

Product · Contact

B08 · POL-EKO sp. z o.o. — Poland

Role: OEM

Product / mapping: CLW15 Smart incubator

Parts / items: 91 — 2 set(s)

Fit: The product page confirms digital PID, shelves and an open-door alarm; komora27l/użytkowa14l.

Gaps: The specification does not state pojemności/zakresu.. Confirm suitability for fiotek/płytek and acceptance of the configuration; do not claim that this is the model specified by the contracting authority.

Status evidence: Official OEM product page and contact, HTTP 200; e-mail sales contact published directly on the product page.

Contact: Rafał Tatarczyk — offer contact named by the OEM; position not published

E-mail: ;

Telephone: +48 32 453 91 70

Availability: 2 sets not confirmed.

Commercial inquiry — prepared, not sent: Would CLW15 Smart in 2 set(s) meet the incubation specification, with a shelf for fiolki/płytki and a door alarm? Please confirm capacity, temperature range, included accessories, price, MOQ, stock status, lead time, calibration, Polish-language documents and warranty.

Product · Contact

B09 · Dometic / Dometic Poland Sp. z o.o. — Poland — Dometic’s own foreign OEM office (Swedish group)

Role: OEM

Product / mapping: CombiCool ACX3 40 9600028409

Parts / items: 92 — candidate only, subject to clarification of intended use

Fit: The current product page confirms 41 l and zasilanie12/230V/gaz, and cooling to 30°C below ambient temperature.

Gaps: This is an absorption refrigerator, not confirmed laboratory equipment with a specified zakresie/stabilności.. Acceptance of 230V instead of 220V, or of the gas version, has not been confirmed.

Status evidence: Official product page and Sales Offices list confirming Dometic Poland, ul. Poleczki 35 in Warsaw, e-mail and telephone number; freshly checked, HTTP 200.

Contact: Dometic’s Polish office in Warsaw — central service channel; not separately confirmed as a sales department address

E-mail: — official channel of the Polish office

Telephone: +48 22 414 3200

Availability: 1 units of the appropriate version not confirmed.

Commercial inquiry — prepared, not sent: Once the temperature requirement has been clarified, please confirm the suitability of ACX3 40 for LL use, 12 V/220–240 V/gazu, gas type and regulator, stability, capacity, price, MOQ, lead time, warranty and Polish channel.

Product · Contact

B10 · Centrum Kempingowe — Poland

Role: Specialist camping supplier; Dometic authorization not confirmed

Product / mapping: CombiCool ACX3 40 version D, DO9600028407

Parts / items: 92 — only after technical clarification

Fit: Actual Polish offer urządzenia12/230V/gaz.

Gaps: Laboratory conformity not confirmed. The Polish store lists SKU 9600028407, while the OEM product page lists SKU 9600028409: do not combine their specifications; confirm the correct gas version.

Status evidence: Product page and official contact consulted on 02.11, both HTTP 200.

Contact: Central service; no named contact published

E-mail:

Telephone: +48 690 680 245

Availability: The product page states out of stock; delivery lead time to be confirmed, not available stock.

Commercial inquiry — prepared, not sent: Please confirm the exact SKU/ciśnienie of gas,12/230V, the possibility of delivering 1 units, price, lead time, warranty terms, documents, the OEM channel and the requirements matrix LL once clarified.

Product · Contact

10 WSK — entire basket 115/2026

Item 1: multiBic family, exact Polish SKU K0/K2/K4 and composition to be confirmed. Item 2: Ci-Ca Dialysate K2/K4 without phosphate. Item 3: Ci-Ca Dialysate K2/K4 Plus with phosphate. Item 4: Sodium Citrate 4% for Ci-Ca. Item 5: Calrecia 100 mmol/l, 1500 ml bag — the OEM data sheet specifies dihydrate CaCl2, 300 mOsm/l and pH 5–7. These are candidates for a full compliance matrix, not a confirmed complete offer.

FMC-PL · Fresenius Medical Care Polska S.A. — Poland

Role: The group's own Polish OEM channel, not an independent reseller

Status evidence: The official Polish contact page lists the company and ordering department. The global OEM data sheet lists the Ci-Ca family; local availability of each SKU requires confirmation.

Contact: Magdalena Godzich — Customer Service Department; no more specific title provided

E-mail: ;

Telephone: +48 61 8392 656 / +48 61 8392 608

Contact

FMC-DE · Fresenius Medical Care AG — Sales & Marketing — Germany

Role: OEM group's foreign head office / product escalation, within the same chain as FMC Polska

Status evidence: The official contact page directs product and availability inquiries to the local representative or Sales & Marketing department. This is not a second independent manufacturer.

Contact: Sales & Marketing; no named sales representative confirmed

E-mail:

Telephone: +49 6172 609 0 (head office)

Contact

OEM: current Ci-Ca family · OEM: multiBic / Ci-Ca / citrate · OEM: Calrecia — 1500 ml specifications

Gaps: Not confirmed: Polish SKU and authorization for each wyrobu/leku, full compatibility of composition and connectors SecuNect/SafeLock, a legal channel for the entire basket, quantity availability, MOQ, lead time, 12 months' shelf life for each batch, price, export terms and guaranteed delivery within 2 business days. Foreign OEM websites do not prove availability or authorization in Poland.

RFQ — not sent: Will the Polish OEM channel quote for the entire basket of 5 items 115/2026, base and option separately, with exact Polish SKUs K0/K2/K4 after the change 26.10, compatible with M201271/M205001 and SecuNect or SafeLock + required adapters? Please provide price netto/VAT, confirmed quantities and schedule, MOQ, shelf life ≥12 months, legal uprawnienia/dopuszczenia, data sheets, warranty, delivery within 2 business days, and any export restrictions.

Changes and monitoring of earlier cases

  • WOFiTM 95/2026, ID 1398397: deadline 02.11,11:00 has passed; the latest listing moved the procurement to ended. It is neither active nor URGENT. The number of bids and the outcome have not been confirmed; the link to dawnym27/2026LOT26 remains product-related.
  • WOFiTM 96/2026, ID 1398400: The public listing is still active, deadline 03.11,11:00; the former lot with no bids has not been identified, so it is excluded from the portfolio's formal ponowień/PILNYCH count. The full current basket and any changes have not been confirmed.
  • 43 WOG 122/21/PN/2026, ID 1396499: ended, deadline 30.10,08:00. Expiry of the deadline does not mean zero bids; the outcome remains unconfirmed.
  • 28 WOG D/110/2026, lot 2: A new procurement of portable air conditioners with ancillary unloading in Biała Podlaska, deadline 10.11,08:00, delivery by 30.11. The overlap with dawnymD91/2026cz.2 concerns produktu/miejsca, formal succession and full identity of the statement of requirements have not been confirmed. Historical 120550,40 PLN net is not the current budget and is not included in today's total. Current notice · Former outcome, lot 2 only.

D110 — MONITOR / NO-BID until gaps are closed. A bid bond is required; the amount is only in the unreadable SWZ; ilości/parametry, warranty and payment terms undetermined. Without the complete statement of requirements, we will not select an arbitrary OEM. Contact: ; phone number not confirmed.

  1. Download the complete current SWZ/OPZ, forms and amendments, and compare old 2→new 2.
  2. Confirm the bid bond and a compliant supplier able to deliver by 30.11, including transport and unloading.
  3. Prepare the Polish price, art. 125, representation and appropriate signature; do not assume OEM authorization is mandatory.
  4. Only after closing the gaps, submit via the appropriate platform by 10.11,08:00 and retain confirmation.